RFSW-06-SP4T-A-U-S

USB-Controlled SP4T RF Switch

Price

On request

Pricing depends on interfaces and scope and is confirmed in a written quotation. Request a quote

Functional connection diagram
SP4T switching example: COM connected to RF path 2 The test instrument is connected to the common port, COM. Only RF path 2 is selected; paths 1, 3 and 4 are unselected. The dashed line carries USB control and power from the control computer. SP4T Test instrument COM RF 1RF 2SelectedRF 3RF 4 USB control and power Control computer

A USB-controlled absorptive SP4T RF switch for 100 MHz to 6 GHz, designed for RF signal routing in automated test setups.

  • 100 MHz-6 GHz
  • Absorptive SP4T topology
  • USB control and power

Revision 2026-11-R1 · EN

Technical values refer to the identified source configuration. The applicable configuration and operating conditions are confirmed at quotation.

Technical specifications
ParameterConditionValueMin.Typ.Max.Unit
Frequency range—100—6000MHz
Impedance——50—Ω
Port-to-port isolation0.1-2 GHz—5060—dB
Port-to-port isolation2-4 GHz—4055—dB
Port-to-port isolation4-6 GHz—3545—dB
Insertion loss<2.5 GHz——2.53dB
Insertion loss<5 GHz——44.5dB
Insertion loss<6 GHz——4.55.5dB
VSWR——1.5:12:1
RF input power———+29dBm
P1dBCOM → active port—3134—dBm
Input IP3COM → active port—5358—dBm
ControlUSB———
Power supply5 V DC / 30 mA (USB)———
RF connectorSMA (f)———
Source body dimensions79.5 x 62.93 x 17———mm
Mass0.26———kg

Applications

  • RF signal routing
  • Automated test equipment
  • Repeated test sequences

Example test sequence

In the connection diagram, the test instrument is connected to the common port, COM. RF 1–4 label the four test paths in this example. When the computer selects path 4 instead of path 2 over USB, COM connects to path 4. Only one RF path is selected at a time.

RFSW-06-SP4T-A-U-S

Let’s define the configuration for your application.

Enquire about this product
Back to all products
Open full-size image